Scalar control of an AC electrical motor is a way to achieve the variable speed operation by manipulating the supply voltage or current ("magnitude") and the supply frequency while ignoring the magnetic field orientation inside the motor.[1] Scalar control is based on equations valid for a steady-state operation[2] and is frequently open-loop (no sensing except for the current limiter). The scalar control has been to a large degree replaced in high-performance motors by vector control that enables better handling of the transient processes.[1] Low cost and simplicity keeps the scalar control in the majority of low-performance motors, despite inferiority of its dynamic performance;[3] vector control is expected to become universal in the future.[4]

Types

edit

The variants of the scalar control include open-loop control and closed-loop control.[5]

Open-loop

edit

The most common approach[3] makes the voltage V proportional to frequency f (so called V/f control, V/Hz control, Constant Volts/Hertz, CVH[3]). Advantage of the V/f variant is in keeping the magnetic flux inside the stator constant thus maintaining the motor performance across the range of speeds. A voltage boost at low frequencies is typically employed to compensate for the resistance of the coils.[1][6]

An open-loop V/f control works well in applications with near-constant load torque and gradual changes in rotational speed. The controllers implementing this method are sometimes called general purpose AC drives.[5]

Closed-loop

edit

If sensors are utilized (closed-loop configuration) for better/faster transitional response, the common approach uses a rotational speed sensor (so called closed-loop V/Hz control).[5] The speed error is passed through the proportional-integral controller to create the accumulated slip difference that is combined with the direct reading of the speed sensor into a frequency control signal.[7]

In a torque-control variant (TC, not to be confused with the direct torque control a.k.a. DTC), the motor torque is held constant in the steady-state, this requires a current sensor.[3] Frequency and flux (voltage or current, depending on the type of the drive[8]) control signals are decoupled, with the flux control driven by the flux estimate, and the frequency control driven by the torque estimate and speed sensor data.[9] The increased performance comes at the cost of additional complexity and associated potential stability issues.[10]

References

edit
  1. ^ a b c Finch & Giaouris 2008, p. 483.
  2. ^ Buja & Kazmierkowski 2004, p. 744.
  3. ^ a b c d Trzynadlowski 2013, p. 43.
  4. ^ Bose 2009, p. 11.
  5. ^ a b c Chan & Shi 2011, p. 3.
  6. ^ Bose 2002, p. 340.
  7. ^ Bose 2002, pp. 342–344.
  8. ^ With the current feedback in place, the motor can be driven using either a voltage-fed inverter or a current-fed inverter.
  9. ^ Bose 2002, pp. 345–346.
  10. ^ Bose 2002, p. 345.

Sources

edit
  • Finch, John W.; Giaouris, Damian (2008). "Controlled AC Electrical Drives" (PDF). IEEE Transactions on Industrial Electronics. 55 (2). Institute of Electrical and Electronics Engineers (IEEE): 481–491. doi:10.1109/tie.2007.911209. ISSN 0278-0046.
  • Buja, G.S.; Kazmierkowski, M.P. (2004). "Direct Torque Control of PWM Inverter-Fed AC Motors—A Survey". IEEE Transactions on Industrial Electronics. 51 (4). Institute of Electrical and Electronics Engineers (IEEE): 744–757. doi:10.1109/tie.2004.831717. ISSN 0278-0046.
  • Trzynadlowski, A.M. (2013). "Scalar Control of Induction Motors". The Field Orientation Principle in Control of Induction Motors. Power Electronics and Power Systems. Springer US. ISBN 978-1-4615-2730-5. Retrieved 2023-10-29.
  • Chan, T.F.; Shi, K. (2011). "Scalar Control". Applied Intelligent Control of Induction Motor Drives. IEEE Press. Wiley. ISBN 978-0-470-82828-1. Retrieved 2023-10-31.
  • Bose, B.K. (2002). Modern Power Electronics and AC Drives (PDF). Eastern Economy Edition. Prentice Hall PTR. ISBN 978-0-13-016743-9. Retrieved 2023-10-31.
  • Bose, Bimal (2009). "The past, present, and future of power electronics [Guest Introduction]". IEEE Industrial Electronics Magazine. 3 (2). Institute of Electrical and Electronics Engineers (IEEE): 7–11, 14. doi:10.1109/mie.2009.932709. ISSN 1932-4529.